HUF EUR USD
Forgotten password
Contents:
0 item: 0 HUF
Main pageProductsOutletManufacturersPrice listDownloadsNewsPresentationsAbout usContact
Products » Discontinued products »  Intrusion  » BENTEL » Control panels » BE KYO 4 NK
Discontinued products BE KYO 4 NK
Discontinued
BE KYO 4 NK
Comparison
Control panel, 4 zones, 4 partitions, without keypad
Control panel, 4 zones, 4 partitions, without keypad 
Information
General information
Maximum Number of Zones
4
Maximun Number of Outputs
4
Max. Length of Communication
500 m is the maximum distance from one module to the panel. The voltage drop of each run have to be less than 1,5 V.
Numbers of Partitions
4
Number of User Codes
24
Number of Keys or cards
128
Telephone numbers
8
Number of wireless Receivers
None
Wireless Key Support
None
Event Buffer
Yes (128)
Details
Power Supplies
Linear 1A
On-board Zones
4
Maximum Number of Wireless Zones
None
Maximum Number of Keypads
8
Zone types/Options
8/6
Supervision Zone
NC/NA EOL DEOL
More than one partition for zone
Yes
Command imput (Keyswitch, reset, attivazione)
Yes
Thresholds setting for zone
No
Vibration/Shock
No
Vibration/Shock sensor imput zones
Up to 4
Bell control outputs
1 Relay - 3A
Number of On-board Outputs
1 relay + 3 PGM
Maximun Number of expanders
-
Output Options
30
Adjustable
Per partition
Supervised bell circuit
None
Type of Communication Bus
BPI Bus
Number of loops
1
Number of Keypads
8
Number of Key/Card readers
16
Number of input expansions
None
Number of output expansions
None
Number of power supply stations
None
Master Codes
Up to 24
Code options
7
Code length
4-6
Central Station Phone Numbers
Up to 8
Account codes
8
SIA
None
Contact ID
Yes
Pulse Formats (3/1, 4/2)
Yes
Phone line monitor
Yes
Backup cellular support
Externally
Periodic test trasmission
Yes
“True” Partitions or Split Arming
Yes
Split Reporting by Partition
Yes
Two-way Capability
Optional (NC2/VOX)
Keypad programming
Yes
Remote Downloading
Yes
Local Downloading
Yes
Communications Baud Rate
1200 (modem) 9600 (nul-modem cable to PC)
Automatic baud rate adjustmen
Yes
Modem Types Supported
B. MOD, B.MOD-RX
Remote monitoring and control
Yes - Bentel Security Suite(Zone-arming/disarming-state-activation-desactivation output, bypass)
Double Call
Yes
Programmable number of Ring
Yes
User-initiated Call-up
Yes
Callback
Yes
Remote Phone Command
Arm, Disarm, Outputs ON/OFF, Telephone call end, available Listen-in and Two way
Automatic Arming
Yes
Timers
-
Delinquency (inactivity)
For partition in Hours
Negligency
For partition in Days
Zone status by voice messages
No
Programmable logical events
No
Continuous voice recording
No
Access control
No
Print product page
Downloadable files
Kyo_4_8_32_upgrade_H...zip1 MB2016.12.13.
1 file

Sütik
Az oldal sütiket (cookie) használ. További információ az Adatvédelmi tájékoztatóban olvasható.

Tudomásul veszem